Paxar 9474 User Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
The zero point is 1.5 mm or 0.060 inches from the left edge of
the supply.
The unit of measurement is tenths of millimeters. The range
must be less than the maximum width of the supply.
Values: 0-1016 (0 to 4 inches)
The following format data stream uses the graphic data defined
earlier in this chapter. The graphic is inserted 20 mm from the
bottom and 20 mm from the left edge of the supply.
{F11,550,507;LETTER-A
p
G1,200,200
p
T0,I,0,400,100,1,1,0,0,B
p
}
The following batch data stream prints the following tag:
{B11,1,1,1,1,0,C;LETTER-A
p
T0;LETTER-A GRAPHIC
p
}
Example
G1,100,40
p
The graphic number 1 is inserted into the format 10 millimeters
from the bottom and 4 millimeters from the left edge of the print
area.
Using Graphics 4-7